QEL Update 6 15 12 - Inbenta
There will be no change to the Von Duprin exit devices or power supply. Backwards compatibility with any PS900 series and existing PS873 applications. The QEL utilizes a motor driven retraction system to more effectively, QEL+ Replacement Kit, replaces 050774 ... Fetch Doc
Recently Von Duprin has discontinued the PS873 power supply and the add-on boards associated with that power supply. Command Access has developed a replacement board ... Fetch Here
What Could Cause A Fuse To Blow - YouTube
What could cause the fuse to blow in a ps873 power supply? . Scranton furnace top 10 causes of electrical problems. The failure of a fuse does, however, nece ... View Video
SECTION 281313.11 - CARD ACCESS SYSTEM - Dashboard
The modification, replacement, Power Supply: Von Duprin PS873-B-871-2, dual battery backed up mini power booster. Power supply cabinets and transformer enclosures shall each be vented in at least two locations and have proper louvers installed. ... View Full Source
*24908386* QEL 33A/35A, 24908386 98/99 Series
This kit can also be used for motor replacement on existing QEL devices. 3. • PS873 Power Supply Plus 871-2, 871-2Q, Problem with the power supply, control switch or wiring 0VDC LED - off Latchbolt - retracted ... Retrieve Full Source
LCN - Architectural Hardware Online Shop - Builders Sale
PS873 x 871-2 Gray (COM) Violet (NO) Cable 761465 to Middle or Control box lock supply rating: 24 VAC, 1.5 A White White Gray (COM) Violet (NO) White White Black Red Cut connector off rectifier, then connect using wire nuts POWER LCN ®! 1. 2. 5. 5.!! ... Fetch Here
Power Supply Cross Reference List - Static-or01.inbenta.com
Options, then the replacement supply can be built from the cross reference table. • no • If a customer needs to replace a legacy power supply which contains logic boards, then PS873: 10” H x 12 ... Fetch Full Source
PS8 Power Supply 1 - Toner Cable Equipment, Inc.
TM PS8 Power Supply 1 GENERAL Power Requirements DO NOT REMOVE POWER SUPPLY COVERS NO USER-SERVICABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL Replacement Parts —When replacement parts are required, be sure the service ... Access Doc
Series 98/99 BuyLine 0724 STEELCRAFT - Sweets
Of replacement. 996L - Standard Series 98/99 Touchbar Exit Devices All Series 98/99 are available with antimicrobial coating. with a PS873 power supply and an 871-2 option card. • Multiple options for monitoring and mechanical dogging are available. Chexit® ... Access Full Source
VON DUPRIN Installation Instructions EPT2 & EPT10
Patent is Pending. Read All Warnings Before Starting Installation! VON DUPRIN Installation Instructions EPT2 & EPT10 Electric Power Transfer 941071_00(1) ... Retrieve Content
Installation Instructions ININST.1001 1790 Touchbar
Installation Instructions 1790 Touchbar Index: † Before Installation Electric power transfer (EPT-2 part No. 012011 EPT-10 part No. 012012) PS873 power supply 120 VAC Outside control EL1790 switch Electric power transfer or pivot! ... View Document
Save $$! POWER SUPPLY APPLICATION CHART
• A value engineering scenario requiring a more cost effective power supply solution than typical high surge current models • Replacement of defective or anaemic interface modules on Von Duprin, Falcon, Adams Rite, Corbin expensive non proprietary type power supply, see website for power ... Fetch Content
Contents
Contents Series 98/99 Exit Devices XP Series Requires PS873-2 power supply. Electric Mortise Lock The E7500 of replacement. 996L - Standard Von Duprin offers an array of trim functions and formats for both panic and fire-rated devices. ... Doc Retrieval
RFI Transmittal - Corpincconstruction.com
This kit can also be used for motor replacement on existing QEL devices. • PS873 Power Supply Plus 871-2, 871-2Q, 873-4TD/AO Option Boards 12 Route Two Wires from QEL Exit Device to Power Supply QEL Exit Device QEL Electrical Load PS900-Series power supply with 900-Series option board(s) ... Fetch Here
What Could Cause A Fuse To Blow - YouTube
It is designed to blow if your vehicle blowing fuse after fuse? There might be a simple explanation. Ps873 power supply provides 2amp at 24vdc or 4amp 12vdc. What Faulty Microwave Capacitor Diagnosis and Replacement - Duration: 8:25. Tanner Tech 1,654 views. 8:25. Home Repair Tips ... View Video
Www.music.fsu.edu
Model PS873 High Amperage Power Supply, 2-zone controller (For use with EL option panic devices ; 24VDC @ 2a or 12VDC @4A; 10H x 12.5W x 5D) PS873-2 SPS208 Replacement for Liebert GXT2-(500, 700, 1000, 1500) RT120 GXT2-7A48BATKIT Battery Kit, Replacement for Liebert GXT2-2000RT120 ... Retrieve Document
Www.music.fsu.edu
Strobe replacement bulb FT-20a, FT-10a, S-100a EP200 Blue LED Marker Light for Code Blue Wall Mount Emergency Phone BL-FS-E27 OptiLED PS873-2 SPS208 Model SMP5 power supply (converts low voltage AC input, to a 6VDC, 12VDC or 24VDC @ 4 amp of continuous supply current output.) SMP5 ... Fetch Document
VON DUPRIN Installation Instructions - Allmar
Supply Wiring for AC supply Solenoid Use crimp connectors to splice field wiring to P1 leads Figure 2 Fit hook on Yellow solenoid wires: 12 VDC, 0.57 A Black solenoid wires: 24 VDC, 0.29 A (also shown on strike label) SOLENOID POWER REQUIREMENTS Use crimp connectors to splice field wiring to ... Access Doc
00510 INSTALLATION INSTRUCTIONS SWITCH KIT (VON DUPRIN 33, 99)
00510 INSTALLATION INSTRUCTIONS SWITCH KIT (VON DUPRIN 33, 99) P: series between the power supply and fail safe magnetic lock. Depressing the exit device pushpad retracts the latch, causing the contact to open, thereby releasing the ... Access Content
Dor-O-Matic Exit Devices - FW Kline
Falcon Dor-O-Matic exit devices are your best choice for narrow stile aluminum doors. Requires PS873-2 minimum power supply. S- latch bolt monitor switch (SPDT). Conversion kits available. Devices are handed. Fasteners: All mounting screws are concealed. Uses all machine screws for ... Fetch Document
Power Supply Portfolio - Access Hardware
• All power supplies and option boards are UL294 Listed. – Schlage Electronics 6A Power Supply. • Q: What do we do if a legacy PS873 is upgraded to a PS914 but it is size constrained or already plumbed? A: ... Fetch Document
VON DUPRIN PS873 TO ACSI 1550K-MD OR 1550-MD INTERFACE USING ...
Interface using acsi rm relay module through use of the rm relay module as shown in the wire diagram below, output 02 of the von duprin ps873 power supply can be used to power and control one acsi 1550k-md or 1550-md elr device for single door applications, ... Doc Viewer